| | |
| | | else if (num == 1) |
| | | { |
| | | //判断这个条码之前的状态是否为NG |
| | | DataSet ds = oCN.RunProcReturn(@"select * from Sb_EquipMentCollection_SN WITH(NOLOCK) where HBarCode='" + HBadCodeSN + "' and HCreateTime<'" + dic["HCreateTime"].ToString() + "' and HResult='NG' and HProcNumber='" + dic["HProcNumber"].ToString() + "'", "Sb_EquipMentCollection_SN"); |
| | | DataSet ds = oCN.RunProcReturn(@"select * from Sb_EquipMentCollection_SN WITH(NOLOCK) where HBarCode='" + HBadCodeSN + "' and HCreateTime<'" + dic["HCreateTime"].ToString() + "' and HResult='NG'", "Sb_EquipMentCollection_SN"); |
| | | |
| | | DataSet ds1 = oCN.RunProcReturn(@"select a.HSourceID,a.HProcID,* from Sc_StationOutBillMain a WITH(NOLOCK) |
| | | inner join Sc_StationOutBillSub_SN sn WITH(NOLOCK) on a.HInterID=sn.HInterID |
| | |
| | | } |
| | | else if (HResult == "NG") |
| | | { |
| | | //反写工序出站单的不良数量 |
| | | oCN.RunProc("update Sc_StationOutBillMain set HBadCount+=1 where HInterID='" + HInterID + "'"); |
| | | ds = oCN.RunProcReturn("select * from Sc_QualityReportBillSub WITH(NOLOCK) where HBarCode='" + HBadCodeSN + "' order by HMakeDate desc", "Sc_QualityReportBillSub"); |
| | | |
| | | if (ds.Tables[0].Rows.Count > 0) { |
| | | string HBadDate = ds.Tables[0].Rows[0]["HMakeDate"].ToString(); |
| | | |
| | | ds = oCN.RunProcReturn("select * from Sc_SourceLineRepairBillMain WITH(NOLOCK) where HBarCode='" + HBadCodeSN + "' order by HMakeDate desc", "Sc_SourceLineRepairBillMain"); |
| | | |
| | | if (ds.Tables[0].Rows.Count > 0) { |
| | | string HRepairDate = ds.Tables[0].Rows[0]["HMakeDate"].ToString(); |
| | | |
| | | if (DateTime.Parse(HBadDate) < DateTime.Parse(HRepairDate)) { |
| | | //反写工序出站单的不良数量 |
| | | oCN.RunProc("update Sc_StationOutBillMain set HBadCount+=1 where HInterID='" + HInterID + "'"); |
| | | } |
| | | } |
| | | |
| | | } else { |
| | | //反写工序出站单的不良数量 |
| | | oCN.RunProc("update Sc_StationOutBillMain set HBadCount+=1 where HInterID='" + HInterID + "'"); |
| | | } |
| | | } |
| | | else |
| | | { |
| | |
| | | //判断长度是否为29位 |
| | | if (HBadCodeSN.Length == 29) |
| | | { |
| | | string str1 = HBadCodeSN.Substring(23, 3); |
| | | string str1 = HBadCodeSN.Substring(18, 8); |
| | | ds = oCN.RunProcReturn("select * from Sc_ProcessExchangeBillMain where HProjectNum like'" + str1 + "-1%'", "Sc_ProcessExchangeBillMain"); |
| | | //判断是否能找到对应的流转卡 |
| | | if (ds.Tables[0].Rows.Count > 0) |
| | |
| | | } |
| | | else |
| | | { |
| | | oCN.RollBack(); |
| | | CustomWriteLog("条码:" + HBadCodeSN + ",流转卡不存在!", DateTime.Now.ToString("yyyy-MM-dd")); |
| | | return 2; |
| | | str1 = HBadCodeSN.Substring(23, 3); |
| | | ds = oCN.RunProcReturn("select * from Sc_ProcessExchangeBillMain where HProjectNum like'" + str1 + "-1%'", "Sc_ProcessExchangeBillMain"); |
| | | //判断是否能找到对应的流转卡 |
| | | if (ds.Tables[0].Rows.Count > 0) |
| | | { |
| | | string HProcExchBillNo = ds.Tables[0].Rows[0]["HBillNo"].ToString(); |
| | | get_HBardBillSave(HBadCodeSN, HProcExchBillNo); |
| | | } |
| | | else |
| | | { |
| | | oCN.RollBack(); |
| | | CustomWriteLog("条码:" + HBadCodeSN + ",流转卡不存在!", DateTime.Now.ToString("yyyy-MM-dd")); |
| | | return 2; |
| | | } |
| | | } |
| | | } |
| | | else |