yangle
2024-10-09 a65397862dafc68ee77646f4162f0155b99a7588
DAL/质检管理/ClsQC_ProcessCheckBill.cs
@@ -123,15 +123,21 @@
                      ",HEntryCloseDate,HCloseType,HRemark,HSourceInterID" +
                      ",HSourceEntryID,HSourceBillNo,HSourceBillType,HRelationQty,HRelationMoney" +
                      ",HQCCheckClassID,HQCCheckItemID,HQCStd,HQCRelValue,HResult" +
                      ",HProcCheckEmp,HProcCheckTime" +
                      ") values("
                      ",HProcCheckEmp,HProcCheckTime,  HSampleSchemeID,HSampleQty,HSampleDamageQty,HAcceptQty" +
                      ",HRejectQty,HSampleUnRightQty,HStatus,HUnitID,HInspectVal,HTargetVal" +
                      ",HUpLimit,HDownLimit,HUpOffSet,HDownOffSet,HKeyInspect,HAnalysisMethod,HInspectInstruMentID,HInspectResult" +
                      ",HQCNote) values("
                      + omodel.HInterID.ToString() + ",'" + oSub.HBillNo_bak + "'," + oSub.HEntryID.ToString() + ",'" + oSub.HCloseMan + "'" +
                      ",getdate()," + Convert.ToString(oSub.HCloseType ? 1 : 0) + ",'" + oSub.HRemark + "'," + oSub.HSourceInterID.ToString() +
                      "," + oSub.HSourceEntryID.ToString() + ",'" + oSub.HSourceBillNo + "','" + oSub.HSourceBillType + "'," + oSub.HRelationQty.ToString() + "," + oSub.HRelationMoney.ToString() +
                      "," + oSub.HQCCheckClassID.ToString() + "," + oSub.HQCCheckItemID.ToString() + ",'" + oSub.HQCStd + "','" + oSub.HQCRelValue + "','" + oSub.HResult + "'" +
                      "," + oSub.HProcCheckEmp.ToString() + ",'" + oSub.HProcCheckTime + "'" +
                      "," + oSub.HProcCheckEmp.ToString() + ",'" + oSub.HProcCheckTime + "'," + oSub.HSampleSchemeID + "," + oSub.HSampleQty +
                      "," + oSub.HSampleDamageQty + "," + oSub.HAcceptQty + "," + oSub.HRejectQty + "," + oSub.HSampleUnRightQty + ",'" + oSub.HStatus +
                      "'," + oSub.HUnitID + ",'" + oSub.HInspectVal + "','" + oSub.HTargetVal + "','" + oSub.HUpLimit + "','" + oSub.HDownLimit +
                      "','" + oSub.HUpOffSet + "','" + oSub.HDownOffSet + "'," + oSub.HKeyInspect + ",'" + oSub.HAnalysisMethod + "'," + oSub.HInspectInstruMentID + ",'" + oSub.HInspectResult + "','" + oSub.HQCNote + "'" +
                      ") ");
                }
                //foreach (Model.ClsQC_ProcessCheckBillSuboSub in DetailColl)
                //{
@@ -236,7 +242,7 @@
                      ",HProcCheckEmp,HProcCheckTime,  HSampleSchemeID,HSampleQty,HSampleDamageQty,HAcceptQty" +
                      ",HRejectQty,HSampleUnRightQty,HStatus,HUnitID,HInspectVal,HTargetVal" +
                      ",HUpLimit,HDownLimit,HUpOffSet,HDownOffSet,HKeyInspect,HAnalysisMethod,HInspectInstruMentID,HInspectResult" +
                      ") values("
                      ",HQCNote,HMax,HMin,HAvg) values("
                      + omodel.HInterID.ToString() + ",'" + oSub.HBillNo_bak + "'," + oSub.HEntryID.ToString() + ",'" + oSub.HCloseMan + "'" +
                      ",getdate()," + Convert.ToString(oSub.HCloseType ? 1 : 0) + ",'" + oSub.HRemark + "'," + oSub.HSourceInterID.ToString() +
                      "," + oSub.HSourceEntryID.ToString() + ",'" + oSub.HSourceBillNo + "','" + oSub.HSourceBillType + "'," + oSub.HRelationQty.ToString() + "," + oSub.HRelationMoney.ToString() +
@@ -244,7 +250,7 @@
                      "," + oSub.HProcCheckEmp.ToString() + ",'" + oSub.HProcCheckTime + "'," + oSub.HSampleSchemeID + "," + oSub.HSampleQty +
                      "," + oSub.HSampleDamageQty + "," + oSub.HAcceptQty + "," + oSub.HRejectQty + "," + oSub.HSampleUnRightQty + ",'" + oSub.HStatus +
                      "'," + oSub.HUnitID + ",'" + oSub.HInspectVal + "','" + oSub.HTargetVal + "','" + oSub.HUpLimit + "','" + oSub.HDownLimit +
                      "','" + oSub.HUpOffSet + "','" + oSub.HDownOffSet + "'," + oSub.HKeyInspect + ",'" + oSub.HAnalysisMethod + "'," + oSub.HInspectInstruMentID + ",'" + oSub.HInspectResult + "'" +
                      "','" + oSub.HUpOffSet + "','" + oSub.HDownOffSet + "'," + oSub.HKeyInspect + ",'" + oSub.HAnalysisMethod + "'," + oSub.HInspectInstruMentID + ",'" + oSub.HInspectResult + "','" + oSub.HQCNote + "','" + oSub.HMax + "','" + oSub.HMin + "','" + oSub.HAvg + "'" +
                      ") ");
                }