WYB
2021-03-22 91b8cdad021ab052e4991f3d41834a6f0ddc36b8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
USE [Jiepei_WMS]
GO
 
/****** Object:  Table [dbo].[SmsLog]    Script Date: 2020/11/18 10:34:46 ******/
SET ANSI_NULLS ON
GO
 
SET QUOTED_IDENTIFIER ON
GO
 
CREATE TABLE [dbo].[SmsLog](
    [Id] [int] IDENTITY(1,1) NOT NULL,
    [UserId] [int] NULL,
    [Mobile] [varchar](20) NOT NULL,
    [SendType] [varchar](50) NULL,
    [Content] [varchar](max) NOT NULL,
    [SendTime] [datetime] NULL,
    [ResponseInfo] [nvarchar](max) NULL,
    [SmsFrom] [varchar](100) NULL,
    [BatchSendNo] [varchar](14) NULL,
PRIMARY KEY CLUSTERED 
(
    [Id] ASC
)WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON, OPTIMIZE_FOR_SEQUENTIAL_KEY = OFF) ON [PRIMARY]
) ON [PRIMARY] TEXTIMAGE_ON [PRIMARY]
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ö÷¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog', @level2type=N'COLUMN',@level2name=N'Id'
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ô±¹¤ID' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog', @level2type=N'COLUMN',@level2name=N'UserId'
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'½ÓÊÕ¶ÌÐÅÕß' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog', @level2type=N'COLUMN',@level2name=N'Mobile'
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'·¢ËÍÀàÐÍ˵Ã÷' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog', @level2type=N'COLUMN',@level2name=N'SendType'
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'·¢ËÍÄÚÈÝ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog', @level2type=N'COLUMN',@level2name=N'Content'
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'·¢ËÍʱ¼ä' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog', @level2type=N'COLUMN',@level2name=N'SendTime'
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'·µ»Ø×´Ì¬' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog', @level2type=N'COLUMN',@level2name=N'ResponseInfo'
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¶ÌÐÅÀ´Ô´' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog', @level2type=N'COLUMN',@level2name=N'SmsFrom'
GO
 
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÖªÐÅÈÕÖ¾±í' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SmsLog'
GO